MODELPROBLEMPROCEDURE
Model 1015won't turn onCheck input voltage 10 to 16 volts dc. Must be negative ground system. Check keypad make sure no damage to keys.
Model 1015won't zero /
shows err
Disconnect weigh bars,rezero unit. Hook one bar up and rezero unit. Do this until bad bar appears.
Model 1015stuck on #Check keypad for damaged area. make sure unit is in "gross" mode. Disconnect bars.
Model 1015scale isn't
weighing right
Check bars. Make sure they are showing the same. Check code number in unit.
Model 1015shows last
ingredient of reciepe
Needs atleast rev. e if not sent in. Do master reset. Need all info. Before doing master reset.
Model 600won't turn onCheck input voltage 10 to 16 volts dc. Must be negative ground system. Check keypad make sure no damage to keys.
Model 600won't zero /
shows err
Disconnect weigh bars,rezero unit. Hook one bar up and rezero unit. Do this until bad bar appears.
Model 600scale isn't
weighing right
Check bars. Make sure they are showing the same. Check code number in unit.
Model 615won't turn onCheck input voltage 10 to 16 volts DC. Must be negative ground system. Check keypad make sure no damage to keys.
Model 615won't zero /
shows err
4 bar indicators= with one bar hooked up the applied weight will show up as 4 times the weight on display.50 x 4 =200
Model 615locked on zero4 bar indicators= with two bars hooked up the applied weight will show up as 2 times the weight on display.
Model 615scale isn't
weighing right
3 bar units = with one bar hooked up the applied weight will show up as 2 times the weight on the display.
50 x 2 =100
Model 615hooking up
to rd-4000 / 6000
The RD needs software version 8.0 to run on farm units.
Model 700won't turn onCheck input voltage 10 to 16 volts DC. Must be negative ground system. Check keypad make sure no damage to keys.
Model 700won't zero / shows err / stuck on #Disconnect weigh bars,rezero unit. Hook one bar up and rezero unit. Do this until bad bar appears.
Model 700scale isn't weighing rightCheck bars. Make sure they are showing the same. Check code number in unit.
Model 700ewon't turn onCheck input voltage 10 to 16 volts DC. Must be negative ground system. Check keypad make sure no damage to keys.
Model 700ewon't zero /
shows err /
stuck on #
Disconnect weigh bars, rezero unit. Hook one bar up and rezero unit. Do this until bad bar appears.
Model 700escale isn't
weighing right
Check bars. Make sure they are showing the same. Check code number in unit.
Model 700ehooked up to rd-712Needs the green wire removed in the rd-712 to work correctly.
Model 715won't turn onCheck input voltage 10 to 16 volts DC. Must be negative ground system. Check keypad make sure no damage to keys.
Model 715won't zero /
shows err /
stuck on #
Disconnect weigh bars, rezero unit. Hook one bar up and rezero unit. Do this until bad bar appears.
Model 715scale isn't weighing rightCheck bars. Make sure they are showing the same. Check code number in unit.
Model 915won't turn onCheck power supply. vr2
Model 915won't zero /
shows err /
stuck on #
Disconnect weigh bars, rezero unit. Hook one bar up and rezero unit. Do this until bad bar appears.
Model 915scale is not
weighing right
Check bars. Make sure they are showing the same. Check code number in unit.
Model 815scale is locked upCheck power supply voltages +8,-8,5 volts.Try using course zero pot without bars hooked up.
4-pin barsb-c=240 / c-d=240 / b-d=480a=shield b= red c=black d=white.
5-pin barsa-c=350 / b-d=350 / a-b=262 / b-c=262 / c-d=262 / a-d=262A=red / b=green / c=white / d=black / e=shield
7-pina =red / b=green / c=white / d=black / e=blue / f=yellow / g=shield 